Forum Post: RE: ADS5294: Need to use SYNC across multiple devices when NOT decimating.

$
0
0
Hello, Chen, In the following sequence that you recommended originally, can you please explain why you asked us to set 0x42 bit 15 to a 1? This seems only to have effect if using it along with bit 3 of the same register and then only if F0(15) is set to 1. 5) Every time before run a new SYNC pulse, please RESET (by setting register) as: (note: this following is the ADS5294 GUI's Software RESET.) (In this setting, we are using 14bit mode, LSB-first, Offset Binary modes) set: Address=0x00, Data=0x0001 set: Address=0x00, Data=0x0000 set: Address=0x42, Data=0x8000 Thanks, Bob