Forum Post: RE: ADS8353: ADS8353 Output Drifting with consecutive measurements

$
0
0
Sorry for the delay, Collin, and thank your for your response. After conducting some testing, it seems likely that is the issue with the count drop with successive measurements. However, it still does not explain why we have an apparently required delay after exiting standby mode. As I explained above, after programming CFR and REFDAC A/B (therefore exiting standby), toggling a wait time seems to be necessary (~8000 cycles, 0.5ms) before the counts settle to reasonable levels. eg expected counts of 450 become 800 without this wait time. Do you have a suggested course of action or culprit for this issue? Am I improperly waking the ADC from standby? Once again I appreciate your assistance in understanding all this. Liam