Forum Post: RE: ADC12DJ3200: Decimation and Sample alignment

$
0
0
Hi Cameron ADC12DJ3200 datasheet section 7.3.5.1.6 NCO Phase Synchronization addresses the additional requirements of initializing the NCO phase. The two basic methods are through use of SYNC or SYSREF. Please review the information in that datasheet section, and let me know if you have any additional questions. Best regards, Jim B