Forum Post: RE: ADS131A04: Irregular sampled data when the difference between two input channels are large

$
0
0
Thanks, Dan. Are the grounds shared between the EVM and your signal generator? A 200-mV input signal should not cause the ADC output to clip like this, especially since all channels are set to Gain = 1 V/V. Also, please show all four channels of data in the scope plot. Even if they are left floating, it's ok. The offsets should look comparable to this: Best Regards,