Forum Post: RE: LMP92066: LMP92066 device version A1 output voltage accuracy

$
0
0
Hi Jan, I checked with our test team and the test program was updated in the time between the two lots were made, but these were minor changes and the performance did not change between them. I assume the ID register was updated to denote the change. So that being said, can you go into more detail about the output error? When you enter override mode, does the output error improve? If you look at the output on an oscilloscope, do you see any oscillations or instability? Thanks, Paul