Part Number: ADS124S06 Dear Sir, I have a question about RDATA command of the section 9.5.4.2 of d/s. About DOUT/DRDY data if SCLK is continuing after all bytes were read which is after CRC were read on Figure 91 of d/s. The d/s describes that DOUT/DRDY will repeat to output from STATUS, Data1 . . . . again and again, is it correct understanding? And what data will be read if SCLK is continuing after the following ADC conversion was completed? Is it still old data before conversion and need another RDATA to get new converted data (by monitoring /DRDY, referring Figure 86), or DOUT_DRDY will send new converted data without RDATA command again? If both using /DRDY or every RDATA command for reading consecutive conversion data work, what is advantage/dis-advantage each? ADS1248 has RDATAC, so I am not sure how or if ADS124S06 will do similar. Best regards, Masa
↧