Forum Post: RE: DAC80508: DAC Error Specs and Voltage Reference

$
0
0
Hi Richard, Thank you for your query. The reference error is not included in the calculation of the total unadjusted error (TUE). Please see this video to understand TUE calculation: training.ti.com/demystifying-circuit-design-precision-dac-part-3 When using an external reference, the new error will be: TUE-new = SQRT((TUE)^2 + (RefError)^2) Considering +/-0.05% as the TUE specified in the datasheet and +/-0.05% external reference error provided by you, we get: TUE-new = 0.07% FSR Hope that answers your question. Regards, Uttam Sahu Applications Engineer, Precision DACs