Forum Post: RE: DAC161S997: 4-20mA current output (DAC161S997) and digital output (16-30V) share the same two terminals, which output mode selected leave to user, any ideas or solution available?

$
0
0
Hi Ma, Understood, the series switch should not cause any issue with the analog 4-20mA signal as long as Ron is reasonably low. I do not have a particular recommendation for these switches but perhaps you could post to the switches & multiplexers forum for a recommendation or use the parametric search tool. Thanks, Garrett