Part Number: DAC81416EVM Hi all, we have a DAC81416EVM board, and it is connected to our spi master. When we read the all readable registers after power-on, all the read values are matched to the initial values as described in the spec. except for the Status register (address 0x02). According to the spec. it should be 0000h, however the measured value is 8000h. The response of the MISO (in red) is shown as following: Is it normal? Thanks in advance! Best regards, Jianxiong
↧