Hello Jonas, Thank you for your post and welcome to our forum! The ADS8354 updates the SDO data on the SCLK falling edge, and reads data from the SDI bus on the SCLK falling edge. The host will need to latch in the data from SDO on the SCLK rising edge. The timing diagram shown in Figure 89 is not drawn perfectly to scale. Please refer to the serial interface timing and associated delays in Figure 1. Best regards,
↧