Hi Hooman Hashemi
As you have suggested, i made INCLK= 8MHz, and initialized the LM98714 according to the figure 64.
My configuration details are given bellow.
Page 0:
Main Configuration 0 = 0xF1.(Mode 3 in forward mode and one color sequence).
Main Configuration 1 = 0x05.(O/P format is CMOS, INCLK = ADCLK).
Main Configuration 2 = 0x08.(Device active,O/P enable,Device fully powered).
Page 2
SH Mode = 0x80( SH o/P pin to tristate,SH source select to external).
CMOS Data Mode = 0x20.(CLK10 is configured as CLKOUT).
Am not using the CCD timing generator so i kept all other registers to default.
After all this configuration, starting the scan by using start scan bit in
Main Configuration 2 = 0x01.
Am polling the ready bit after start scan, and it is working as expected (shown in fig 64).
I am observing some pulses on output pins but am not getting any pulses on CLKOUT pin.
Regards
Govind Raj