Forum Post: RE: LM98725 black calibration

$
0
0
Hi Elnur Thanks for the detailed information, that is very helpful. I have reviewed the sensor datasheet and your register settings. The only register value I have some concern about is the Black Target (Page 2, Register 0x03h) value of 0 decimal. A value this low may cause the search/feedback algorithm to have some problems. Have you tried using larger values of Black Target? I would recommend a target value of at least 16 decimal. Or you could try starting with the default value of 0x40h (64 decimal) and then lower it until you find the point that problems occur. Best regards, Jim B