Hi Yuan, The TX-SDK-V2 that you've identified includes some of the blocks you are looking for: LM96530 Octal T/R Switch LM96550 Octal High Voltage Pulser LM96570 Octal Digital Beamformer The LM96511 is the AFE receiver that can be used. I cannot comment on whether or not you can attain the range (meters) that you've noted. However, maybe you can use the LM96511 (receiver) RTI (Returned To Input) of 0.9nV/RtHz spec to do a rough calculation of the attainable distance? Regards, Hooman