Forum Post: RE: ADS1115: Device Reset Operation during Supply Voltage Transient

$
0
0
Hi Joseph, Thanks for your prompt reply! I am checking the BMS in bench test. The VDD of ADS1115-Q1 is pretty stable during the relay switching period and continuous communication was also monitored on the I2C interface. So I think the interface components are properly functioning. I think checking the OS bit could help to determine whether POR is triggered or not if ADS1115-Q1 was set to continuous conversion mode previously. Are there any ways could help to tell the rest of ADS1115-Q1 in normal operation? For example, could reading some specific fields in the register map help to tell the analog part is functioning well? Peiheng.