Forum Post: RE: ADS124S06: Differential measurement and ADC counts output

$
0
0
Hi Surya, unfortunately this is not possible with ADS124S06 . The LSB size is fixed to (2 x VREF) / (2^24 x Gain) independent of using single-ended or differential measurements. Reducing the LSB size would actually not help to improve the performance because the noise of the ADC is larger than the LSB size. Regards,