Forum Post: RE: LM98714: LM98714 reset timing and SPI slew rate criteria

Hi Alex, 1. This is a non spec parameter. My recommendation is min reset time at least 4 INCLK. That's no max time limitation. 2.This is a spec parameter: LVDS Output: Min=180mV, Max=450mV with...

View Article


Forum Post: RE: Find Ultrasound Transmit Solution Evaluation Board

Hi user4672467, Is your application air-coupled or liquid-coupled? What kind of detection range do you need? We have two recommended devices for ultrasonic sensing, the TDC1000 and the PGA460 . Both...

View Article


Forum Post: RE: Find Ultrasound Transmit Solution Evaluation Board

Thank you for the replying. My application is liquid-coupled, as medical ultrasound imaging device. The maximum frequency is 15 MHz or more, that we want to receive. And hope the pulser have Negative...

View Article

Forum Post: RE: Find Ultrasound Transmit Solution Evaluation Board

Hi user4672467, If you are looking for medical ultrasound applications, neither the TDC1000 nor the PGA460 will work. TI has a wide range of medical ultrasonic sensing devices, though I do not work in...

View Article

Forum Post: Search Ultrasound develop Evaluation Board to qiuck design...

When TX-SDK-V1/NOPE and TX-SDK-V2/NOPE were discontinued by the manufacturer, that I can't find any alternative? I want to develop Ultrasound single/Multiple element pulser , that I need Ultrasound...

View Article


Forum Post: RE: Find Ultrasound Transmit Solution Evaluation Board

Hi Kristin Jones, Thanks for help. I asked one more question at Ultrasonic sensing Forum. I am not find any evaluation board I want at the homepage you told me. Thank you again.

View Article

Forum Post: RE: Search Ultrasound develop Evaluation Board to qiuck design...

Hello, The TX-SDK-V1 and TX-SDK-V2 EVM have been made obsolete and currently we do not offer any alternative or replacement as a whole kit. Here is a possible signal chain that you could look into for...

View Article

Forum Post: VSP5611: VSP5611

Part Number: VSP5611 hi, Our company is planning to do scanners, scanners that can scan A4 paper, currently searching for VSP5611 from the Internet, but do not know how to build this imaging function?...

View Article


Forum Post: RE: VSP5611: VSP5611

Hello Eric, We have received your inquiry about the system level question related to VSP5611 . I am checking with my team and will get back to you by mid next week.

View Article


Forum Post: RE: Find Ultrasound Transmit Solution Evaluation Board

Hi user4672467, I am assuming you were able to find the ultrasonic sensing homepage on www.ti.com I will close this thread. If you have any questions, please feel free to open a new post.

View Article

Forum Post: RE: VSP5611: VSP5611

Hello Eric, I will be closing this thread due to inactivity, if you have further questions feel free to ask a new question. Thanks

View Article

Forum Post: LM98714: LM98714 LVDS Output Timing issue

Part Number: LM98714 Dear Sir, The LM98714 datasheet show LVDS output timing the TXCLK leading TXOUTx. Our customer measure waveform is TXOUTx leading TXCLK. Please refer below waveform. Need you help...

View Article

Forum Post: RE: LM98714: LM98714 LVDS Output Timing issue

Hi Sam, I have notified our expert regarding this issue. Please expect a response by Monday, June 11th. Regards, Aaron

View Article


Forum Post: RE: LM98714: LM98714 LVDS Output Timing issue

Hi Sam, TXCLK should lead TXOUT based on design simms and characterization with finclk=45MHz, the prop delay can not be adjusted. My suggestion is to set LVDS test mode1 and to trigger the output...

View Article

Forum Post: RE: LM98714: LM98714 LVDS Output Timing issue

According to the datasheet, the clock edge be ahead or behind data edge. The +/- describe its relation based on the 45Mhz testing condition.

View Article


Forum Post: RE: LM98714: LM98714 LVDS Output Timing issue

Hi Sam, Your initial question was about LVDS prop delay, scope screenshot is the LVDS output. 98714 LVDS spec: I'm expecting better than your measurements prop delay at finck=16MHz, if needed I can...

View Article

Forum Post: RE: VSP5610: The output is not proportional to the gain

Hi ACGUY, Since there is no activity on the post, I am closing it for now. If you hear back from your customer on the register settings, please post it as a new thread.

View Article


Forum Post: RE: AFE5805EVM: Exact kits that I should buy to create a test...

Hi Amol, I am closing the post. If there are any pending questions, feel free to start a new post.

View Article

Forum Post: LM98725: Sample schematic on data sheet

Part Number: LM98725 We would like to use LM98725 by new product. ( New camera ) 8.1 Layout example in LM98725 datasheet, what part of number is CCD device. Can LM98725 make each vartical signal and...

View Article

Forum Post: RE: Search Ultrasound develop Evaluation Board to qiuck design...

Hello, I am closing this post for now. If there are any pending questions, feel free to start a new post.

View Article
Browsing all 28678 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>